Integration

    Downstream

    images/download/attachments/20420572/downstream_UI.png
    The Downstream configuration

    By enabling the downstream publishing the JMS publishing in case of changes is controlled.

    The image format for the fused structure in the published message can be set (mol:V3 format is the default setting).

    The Downstream publishing cron job interval is not available from version 20.8.0-2005111440.

    Identifiers

    LnbRef and Lot Id settings

    Setting Description
    Validate LnbRef Controls if LnbRef should be validated against the regular expressions during the registration
    LnbRef regular expressions List of regular expressions used to validate the submitted LnbRef
    Autocomplete empty LnbRefs Registration is made even if no LnbRef is provided. After registration LnbRef field will be updated with the LN value.
    Lot Id required Controls if the existence of Lot Id should be validated during the registration
    Lot Id unique Controls if the uniqueness of Lot Id should be validated during the registration

    Internal Id settings

    Setting Description DefaultValue
    Id Generator Class Class name of the corporate ID generator com.chemaxon.registry.identifier.DefaultSequenceGenerator
    PCN allocation limit Maximum number of IDs that can be allocated for external use 1000
    ID generator configuration(JSON) Configuration of the built-in ID generator #constant prefix/sufix of a parent identifier: pcn.cnst #pcn separator (if any): pcn.separator #increment type (Field.DataType enum value): pcn.increment #format placeholder for increment value #decimal format: pcn.increment.format   #constant prefix/sufix of a version identifier: cn.cnst #cn separator (if any): cn.separator #increment type (Field.DataType enum value): cn.increment=STRING #format placeholder for increment value: cn.increment.format #specify structure field additional data format like this: additionalData.project: cn.str.field #cn is composed of PCN + cn increment   #constant prefix/sufix of a lot identifier: ln.cnst #ln separator (if any): ln.separator #increment type (Field.DataType enum value): ln.increment #format placeholder for increment value: ln.increment.format #specify structure field additional data format like this: additionalData.project: ln.str.field #ln is composed of PCN + ln separator + ln increment ! make sure its unique { "cn.increment.format": "%s", "pcn.str.field": "", "ln.increment.format": "%03d", "cn.cnst": "", "pcn.sequence.format": "pcn.cnst, pcn.increment", "pcn.increment": "INT", "cn.increment": "STRING", "ln.start": "1", "pcn.increment.format": "%d", "ln.sequence.format": "pcn.cnst, pcn.increment, ln.separator, ln.increment", "ln.separator": "-", "cn.separator": "", "ln.cnst": "", "pcn.cnst": "CXN", "ln.str.field": "", "pcn.start": "1", "cn.str.field": "", "cn.sequence.format": "pcn.cnst, pcn.increment, cn.increment", "ln.increment": "INT", "cn.start": "A", "pcn.separator": "" }
    images/download/attachments/20420572/admin17.png
    The setting of the Identifiers

    Links

    images/download/attachments/20420572/admin18.png
    The setting of the links to third party applications